GES Studio Living module completed on site

[Explore Technology]

GES modular technology

One core platform. Three certification paths.

12.0 × 4.5 × 3.1m. 54m². Built and inspected to 91% completion before it leaves the factory.

Scroll to explore

[Platform]

Built in the factory, not out in the weather

Frame, envelope, wet rooms and services are installed indoors and signed off before dispatch. Three tasks are left for the site: foundations, crane-in, connection. Everything that decides quality happens where it can be measured.

91%
Complete before leaving the factory
4–6weeks
Production time per module
54m²
Usable area per module

[System]

What is fixed, and what you choose

Frame, wet core and services repeat on every module. Layout, envelope and configuration are where one project differs from the next.

[Structure]

One module is a finished product

Living, kitchen and a fixed wet core sit on one 12,000 × 4,500mm footprint. The wet rooms are fitted and water-tested before the module leaves the line.

Because the wet core never moves, pipe runs and waterproofing repeat identically.

See Studio Living 01 details →
GES module plan: dining, kitchen, wet core and living zone

Living layout · 1 bedroom

GES module plan with two bedroom zones and fixed wet core

2-bedroom layout

[Envelope & finish]

Same technical core, different outer layers

Panels, glazing, flooring and palette change per project. The structure and MEP underneath do not, so a new look costs no new engineering.

GES Studio Living 02 in a garden, navy frame and cream panels

Palette · Navy / Warm grey

GES modules combined into a coastal villa configuration

[Configuration]

From one module to a cluster, or stacked

Join along the long edge, wrap around a courtyard, or stack two storeys. Every configuration uses the same frame and the same connection points.

Two GES modules stacked as a two-storey home with deck and pool

Two-storey stack

[Production line]

Six stages before the module leaves the yard

Each stage has a checkpoint and only advances when it passes. That is why module ten matches module one.

Request technical pack
  1. Steel frame

    Galvanised Q355 steel cut, welded and positioned on fixed assembly jigs.

    Dimensional and squareness check against jig

  2. Wet core

    Complete bathroom pod: waterproofing, fixtures, supply and drainage.

    Water and pressure test on pipework

  3. MEP rough-in

    Electrical, plumbing and ventilation routed in panels, terminating at connection stubs.

    Insulation test, pipe pressure test

  4. External envelope

    75/100mm sandwich panels for walls, roof panel with membrane and glazing frame.

    Water tightness and thermal bridge check

  5. Interior fit-out

    Linings, paint, vinyl plank flooring, joinery, sanitaryware and lighting.

    Surface and fixture acceptance

  6. Inspection & dispatch

    Full module inspection, protective wrapping and transport securing.

    Handover checklist with module record

GES module installed and completed on site

[On site]

Three days on foundations, not three months on scaffolding

Foundations are poured while the module is still on the line. When it arrives, a crane sets it on the footings and the crew connects services, treats joints and commissions.

Get a project quote

Less waste, fewer trips, less heat

The benefit does not come from a green gadget. It comes from moving most of the work indoors.

GES module installed cleanly on finished ground

No wet trades on site

No concrete pour, no fired brick, no tile cutting in the field. Dust and site waste drop sharply.

GES module with bolted steel frame and panel system

Demountable frame and panels

A bolted steel structure can be dismantled, relocated or reused instead of demolished.

GES module with insulated sandwich panel envelope

Continuous insulated envelope

Sandwich panels limit thermal bridging, which lowers cooling load for the life of the building.

GES module prepared for dispatch

Fewer delivery runs

Materials arrive at the factory in bulk, and the module reaches site in one trip.

Two completed GES modules stacked

Materials cut to jig

Drawing-led cutting and jig assembly control offcuts, sorting and reuse right on the line.

[Variants]

Three variants, one platform

Same frame, same finish across all three. Only the fire rating and certification path change.

Get full spec sheet
GES-SL-01 Base module

GES-SL-01

Base

Standard configuration for housing and accommodation, NCC engineering documentation.

  • Navy
  • Dark brown
  • Terracotta
  • Light grey
  • Off white
View details →
GES-SL-02 Fire-rated module

GES-SL-02

Fire-rated

Same core platform, with fire-rated build-up and FRL 60/60/60 certification.

  • Navy
  • Dark brown
  • Tan
  • Sand
  • Off white
View details →
GES Project Custom module

Project

Custom

Project-specific dimensions, envelope and certification path.

  • Graphite
  • Dark brown
  • Signal red
  • Light grey
  • Off white
View details →
Specification by variant
SpecificationBaseFire-ratedCustom
Module size12.0 × 4.5 × 3.1m12.0 × 4.5 × 3.1mProject-specific dimensions
Fire ratingNo fire rating required (standard)FRL 60/60/60 (structure, walls, roof)Per project requirements
Structural frameGalvanised Q355 steel frameGalvanised steel with fire protection layerCalculated per project documentation
Floor system18mm floor panel with insulationFire-rated floor with insulationFloor build-up per specification
Wall system75/100mm insulated sandwich panelFire-rated wall panel min. FRL 60/60/60Envelope and insulation per selection
Roof & envelopeInsulated roof panel with membraneFire-rated roof with membraneRoof and facade per project
Wet corePre-fitted wet pod, plumbed and drainedFire-rated wet pod with fire valvesPod or bespoke solution per spec
Interior finishStandard lining and paint, vinyl plank floorFire-rated lining and doors, vinyl plank floorMaterials and fixtures per project scope
ApplicationStandard housing and accommodationProjects requiring higher fire performanceBespoke application per project
Certification pathNCC engineering documentationNCC documentation with FRL certificationPerformance solution per project